• Generac Power Series ATS, 600V, 100-1600 amp, Open with Inphase and Delayed Transition

Generac Power Series ATS, 600V, 100-1600 amp, Open with Inphase and Delayed Transition

Generac contactor type transfer switches are double-throw and interlocked with an over center design to ensure safe, positive transfer between power sources. The switches are 3 cycle rated to ease breaker selection and coordination. The mechanism is field proven and operated via a reliable, compact solenoid for high speed transfer of loads between power sources. The contactors are silver composite for long life, resisting pitting or burning. The switches are rated for full load transfers in critical operating, emergency, legally required, and optional power systems.

The microprocessor based controller is flexible with extensive programmable options. The standard product offers both open with inphase and delayed transition. The 2 line- 32 character LCD displays real time and historical information with time-stamped events. The integrated plant exerciser is configurable run time. With the standard features of pretransfer contacts, 3 phase sensing on utility and generator sources, phase unbalance, phase reversal, load shed/emergency inhibit and communications (Modbus RTU)

Category:

Description

Generac contactor type transfer switches are double-throw and interlocked with an over center design to ensure safe, positive transfer between power sources. The switches are 3 cycle rated to ease breaker selection and coordination. The mechanism is field proven and operated via a reliable, compact solenoid for high speed transfer of loads between power sources. The contactors are silver composite for long life, resisting pitting or burning. The switches are rated for full load transfers in critical operating, emergency, legally required, and optional power systems.

The microprocessor based controller is flexible with extensive programmable options. The standard product offers both open with inphase and delayed transition. The 2 line- 32 character LCD displays real time and historical information with time-stamped events. The integrated plant exerciser is configurable run time. With the standard features of pretransfer contacts, 3 phase sensing on utility and generator sources, phase unbalance, phase reversal, load shed/emergency inhibit and communications (Modbus RTU)

Additional information

Input Voltage

600VAC

Input Frequency

50/60Hz

Output Voltage

600VAC

Output Frequency

50/60 Hz

Certifications/safety

Ul1008, NFPA 70, 99 110 & 37, NEC 700, 701, 702 & 708, ISO9001, 8528, 3046, 7637, Pluses #2B, 4, NEMA ICS10, MG1, 250, ICS6, AB1, ANSI C62.41, Seismic: IBC 2008, CBC 2010, IBC 2012, ASCE 7-05, ASCE 7-10, ICC-ES AC-156 (2012), IEC 6100 EMC Testing and Meas

Brand Name

Generac

Product Brochure

generac_power_series.pdf